Brand Name :iqualitrol
Model Number :PM5 Gen2
MOQ :1 Set
Payment Terms :T/T
Supply Ability :10 Sets per Month
Delivery Time :5 Working Days
Packaging Details :Carton Box
Model :PM5 Gen2, support different frequencies and different types of single crystal probes
Measurement Mode :P-E(Pulse-Echo Method):Measure the time interval between initial pulse and the first back-wall echo
Thickness Range :0.01 mm-38 meters, depending on the material,
Display :2.4 inch (320*240 dot matrix)TFT color display LCD screen
Capacity :Store 100,000 thickness values and 400 parameter configuration files, equipped with host computer software and USB disk
Calibration Methods :Zero calibration type, calibrate sound velocity, one-point calibration, two-point calibration, set sound velocity, material sound velocity table.
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

High-Precision and Multi-Function Ultrasonic Thickness Gauge PM5 Gen2

Brief Introduction:

PM5 Gen2 thickness gauge is an advanced ultrasonic thickness gauge with a variety of standard measurement functions and special feature options.

This portable thickness gauge uses different frequencies and different types of single crystal probes to meet most measurement requirements.

With wide measurement range, it can accurately measure thickness range from 0.15mm thin steel plates to tens of meters long steel rods, and even tens of microns of ultra thin paint layers.

The full-featured PM5 Gen2 can be used for almost all thickness measurement applications.

Technical Specifications:

Measurement Principles and Parameters
Measurement Mode

P-E(Pulse-Echo Method):Measure the time interval between initial pulse and the first back-wall echo.

I-E(Interface Wave-Echo Method):Measure the time interval between the delay block echo and the first back-wall echo.

I-E-E(Echo-Echo Method):Measure the time interval between two consecutive back- wall echoes.

I-ME(Multiple Echo Method):Measure the time interval between multiple backwall echoes.

E-EV(Double Echo Verification):In E-EV mode,three echoes are required.

COAT Mode(Optional):This is coating specific measurement mode.

OXIDE Mode(Optional):Specially designed to measure the thickness of the oxide layer on the inner wall of boiler tube.

PELR Mode (Optional):When the material thickness exceeds the measuring range, this mode needs to be selected.

Probe Types Standard delivery single D15A probe, options: delay line probes, contact probes, protective film probes, pen type probes, water immersion probes and high temperature probes.
Calibration Methods Zero calibration type, calibrate sound velocity, one-point calibration, two-point calibration, set sound velocity, material sound velocity table.
Indication Error

±0.01

±0.05
±(0.5%H+0.01)

H ≤ 3mm
3<H<10mm

10mm ≤ H

Note: H represents the thickness of the tested material.
Thickness Range

0.01 mm-38 meters, depending on the material, probe surface conditions, temperature and selected configuration.

0.15mm-30mm (standard D15A probe, steel)

Material Sound Velocity Range 310-18699m/s, the sound velocity can be calculated for objects with known thickness.

Resolution

Low Resolution:0.1mm
Standard Resolution:0.01mm High Resolution:0.001mm
Ultra High Resolution(Optional):0.0001mm or 0.1um(I-ME)
General Specifications:
Working Language English
Measurement Units mm, inch, μm, mil
Temperature Range -10℃-50℃
Instrument Housing Impact-resistant, waterproof, gasketed casing, interface seal on the casing, designed to IP67 standards.
Size 153mm×76mm×37mm(H×W×D)
Weight 280g including batteries
Power 2 AA size batteries, operating time is more than 24 hours.
Display
Display 2.4 inch (320*240 dot matrix)TFT color display LCD screen
Rectification Mode Radio frequency, Inverter radio frequency, full wave, positive half wave, negative half wave.
View Mode A Scan mode,
B Scan mode,
value mode,
normal, maximum value capture, difference value, over-limit alarm.
Built-in Data Logger Option
Data Logger Identify, store, recall, clear, and transmit thickness readings, waveform images, and instrument configuration etc.by a standard USB port.
Capacity Store 100,000 thickness values and 400 parameter configuration files, equipped with host computer software and USB disk.
Communication in Real Time Option The host computer controls the instrument and transmits thickness values, waveforms and parameters in real time, including the host
computer measurement software. suitable for online measurement and secondary development.
Multi-Channel Option Includes host computer multi-channel measurement software, mainly used for automated thickness measurement.

High-Precision and Multi-Function Ultrasonic Thickness Gauge PM5 Gen2

Inquiry Cart 0